Author Kurtz et al.
Field J Hip Surg
Year 2018

The authors hypothesized that unplanned readmissions, which are often caused by infections and dislocation, may be reduced with ceramic bearing usage. They also sought to confirm that the readmission rates for ceramic bearings were associated with the year of surgery. The authors also found that C-PE bearings were associated with significantly reduced readmission risk relative to M-PE at 30 days (hazard ratio [HR]: 0.91, p < 0.001) and 90 days (HR: 0.93, p < 0.001). In terms of strength of association with 90-day readmission, however, it was ranked the ninth most associated independent factor. To the authors' knowledge, this is the first study to demonstrate an association between THA implant characteristics (in this case C-PE bearing usage) and reduced readmission rates in this context along with patient- and clinical-related factors. The readmission rates for COC were found to be comparable to M-PE.

Author Kurtz et al
Field J Arthroplasty
Year 2017

The purpose of this study was to analyze whether the cost for ceramic-on-polyethylene (C-PE) and ceramic-on-ceramic (COC) bearings used in primary total hip arthroplasty was changing over time, and if the cost differential between ceramic bearings and metal-on-polyethylene (M-PE) bearings was approaching the previously published tipping point for cost-effectiveness of $325. Patient and clinical factors had a far greater impact on the cost of inpatient THA surgery than bearing selection. Because we found that costs and cost differentials for ceramic bearings were decreasing over time, and approaching the tipping point, it is likely that the cost-effectiveness thresholds relative to M-PE are likewise changing over time and should be revisited in light of the present study.

Author MacDonald et al.
Field J Arthroplasty
Year 2017

The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties.The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, researchers found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery.

Author Kurtz et al.
Field J Arthroplasty
Year 2017

The purpose of this study was to analyze the outcomes of ceramic bearings used in primary total hip arthroplasty (THA) in the Medicare population. As in previous studies, researchers found that ceramic bearings have similar overall revision risk as M-PE bearings in primary THA at 8-9 years of follow-up. The results indicate that, after adjusting for selection bias and various confounding patient-, surgeon-, and hospital-related factors, Medicare primary THA patients treated with ceramic bearings exhibit lower risk of infection than those treated with M-PE bearings. In addition, C-PE bearings were associated with lower risk of dislocation and mortality.

Author Kurtz et al.
Field J Arthroplasty
Year 2016

The purpose of this study was to analyze the utilization and outcomes of ceramic bearings used in revision total hip arthroplasty (R-THA) in the Medicare population. A total of 31,809 patients aged >65 years at the time of revision surgery who underwent R-THA between 2005 and 2013 were identified from the United States Medicare 100% national administrative claims database. Medicare patients treated in a revision scenario with ceramic bearings exhibited similar risk of rerevision, infection, or mortality as those treated with metal-on-polyethylene bearings. Conversely, researchers found an association between the use of specific ceramic bearings in R-THA and reduced risk of readmission (C-PE) and dislocation (COC).